Hi,

I've just having some new UPVC windows installed into my house which are being finished today. Everything looks OK apart from the bay window and a small back window. The bay window has a 20mm frame extender inserted at one end and the back window has a 20mm - 30mm gap at one end that's been filled with foam.
The installers said they couldn't fit a frame extender in the back window as it was slightly to narrow at one point along the gap but they will make it look OK with some plastic trim. This is one of the largest UPVC companies in England and I have read some bad feed back on the net since signing my contract so my questions are:-
Are frame extenders acceptable as these should be made to measure?
What should I do as I haven't parted with any cash yet?

Can anyone advise?
Jason
Reply With Quote
  #2 (permalink)  
Old 07-14-2007, 06:07 AM
ginger ginger is offline
Senior Member
 
Join Date: Jan 2003
Posts: 198
Frame extenders within reason (and 20 mm is within reason) are acceptable

Indeed there can be times when you HAVE to use frame extenders just because of internal plaster thickness etc - to make sure the glass is not covered by plaster
Reply With Quote
  #3 (permalink)  
Old 03-13-2008, 10:47 AM
Mervs77 Mervs77 is offline
Junior Member
 
Join Date: Mar 2008
Posts: 4
Hi, I have a similar problem in that I had UPVC windows installed on my L-shaped bay on tuesday. When they installed the windows there was a 35-40mm gap at the top which was filled with Foam. Is this acceptable as I thought it should only be 20mm max. I had them stop work and called the surveyoer out and asked if the windows had been measured incorrectly. They fobbed me off saying that they could not determine the true height of the old PVC windows as it was hidden by the trim. They said everything would be fine once it was covered with the trim.

It may look ok but is this gap acceptable or will it cause problems with draughts in the the future?
Reply With Quote
  #4 (permalink)  
Old 05-13-2008, 09:58 PM
Witchfinder General Witchfinder General is offline
Junior Member
 
Join Date: May 2008
Location: Essex
Posts: 5
Another reason for using frame add ons is if you have an opening window that could hit a soffit board above. Once I fitted a window and failed to take into consideration the soffit board above. When the window was fitted the casement would only go so far about 5 inches before it hit the soffit. Hence I had to get the window remade with a packer added.
Reply With Quote
  #5 (permalink)  
Old 05-14-2008, 08:08 AM
Mervs77 Mervs77 is offline
Junior Member
 
Join Date: Mar 2008
Posts: 4
Thanks for the info guys. They came round to insert the addins and all appears to be fine now.
Reply With Quote
Reply


Thread Tools
Display Modes

Posting Rules
You may not post new threads
You may not post replies
You may not post attachments
You may not edit your posts

vB code is On
Smilies are On
[IMG] code is On
HTML code is Off
Trackbacks are On
Pingbacks are On
Refbacks are On


Powered by vBadvanced CMPS v3.0 RC1

All times are GMT. The time now is 09:47 PM.


Powered by vBulletin® Version 3.6.8
Copyright ©2000 - 2008, Jelsoft Enterprises Ltd.
Search Engine Optimization by vBSEO 3.0.0
Copyright © eBuilders Ltd
1 Townsend Court, Reepham, Norfolk, NR10 4LD
Tel: 0870 580 8083 - International: +44 1603 879423 - Fax: 01603 873112
Registered in England 3404409
All rights reserved

Please Click here to Contact Us